P0206 is a generic OBD-II diagnostic trouble code that indicates the powertrain control module (PCM) has detected an electrical fault in the fuel injector control circuit for cylinder 6. The fault typically involves abnormal resistance, an open circuit, or a short to ground or power in the wiring, connector, or the injector's solenoid coil.
The most common cause. The internal coil of the injector can develop an open circuit, short, or out-of-spec resistance over time due to heat cycling and electrical stress.
The injector harness is often routed near hot exhaust components or sharp engine brackets, and insulation can melt or wear through, causing an open or short circuit.
Injector connectors are exposed to heat, oil, and vibration. Corroded pins, oil-soaked seals, or terminals that lose tension can interrupt the circuit.
Some injectors share a common feed or ground wire. Corrosion or a broken splice elsewhere in the harness can mimic an injector failure on cylinder 6.
Although less common on individual-cylinder codes, a marginal relay or corroded fuse contact that drops voltage to the injector bank can trigger the code.
Rare. The transistor that controls the cylinder 6 injector inside the PCM can fail, but this should only be considered after the injector, wiring, and connectors have all been ruled out.
No. Despite what some sources claim, the PCM is one of the least common causes of P0206. The injector itself and its wiring/connector account for the vast majority of cases. The PCM should only be suspected after the injector and the entire harness have been electrically verified.
Short trips at low load are usually possible, but the engine will run poorly, fuel economy will drop, and unburned fuel can overheat and damage the catalytic converter. The vehicle should be diagnosed promptly.
Not necessarily. If the other injectors test within specification and the mileage is not extremely high, replacing only the failed cylinder 6 injector is acceptable. Replacing the full set is an option on high-mileage engines as preventive maintenance.
No. Clearing the code only erases the stored fault; the underlying electrical problem remains and the code will return as soon as the PCM re-detects the circuit fault.